  • <tr id='1Lmj1z'><strong id='1Lmj1z'></strong><small id='1Lmj1z'></small><button id='1Lmj1z'></button><li id='1Lmj1z'><noscript id='1Lmj1z'><big id='1Lmj1z'></big><dt id='1Lmj1z'></dt></noscript></li></tr><ol id='1Lmj1z'><option id='1Lmj1z'><table id='1Lmj1z'><blockquote id='1Lmj1z'><tbody id='1Lmj1z'></tbody></blockquote></table></option></ol><u id='1Lmj1z'></u><kbd id='1Lmj1z'><kbd id='1Lmj1z'></kbd></kbd>

    <code id='1Lmj1z'><strong id='1Lmj1z'></strong></code>

    <fieldset id='1Lmj1z'></fieldset>
          <span id='1Lmj1z'></span>

              <ins id='1Lmj1z'></ins>
              <acronym id='1Lmj1z'><em id='1Lmj1z'></em><td id='1Lmj1z'><div id='1Lmj1z'></div></td></acronym><address id='1Lmj1z'><big id='1Lmj1z'><big id='1Lmj1z'></big><legend id='1Lmj1z'></legend></big></address>

              <i id='1Lmj1z'><div id='1Lmj1z'><ins id='1Lmj1z'></ins></div></i>
              <i id='1Lmj1z'></i>
            1. <dl id='1Lmj1z'></dl>
              1. <blockquote id='1Lmj1z'><q id='1Lmj1z'><noscript id='1Lmj1z'></noscript><dt id='1Lmj1z'></dt></q></blockquote><noframes id='1Lmj1z'><i id='1Lmj1z'></i>

                KYL-300M

                PRODUCT > RF MODULES > KYL-300M

                KYL-300M

                Features

                 

                1.Power transmission

                  Low power transmission with 2W,High Receiver sensitivity -123dbm(1200bps);-118dbm(9600bps),
                 Small size 80mm&times;45mm&times;20mm (Without Antenna connector)

                2.With 433MHz as factory default carrier frequency, 400~470MHz ISM frequency is available if needed.

                3.High anti- interference and Low BER (Bit error Rate)

                  Based on the Gaussian Frequency Shift Keying (FSK/GFSK) modulation, the high-efficiency forward error correction
                  channel encoding technology is used to enhance data’s resistance to both transient interference and random interference and
                 the actual bit error rate of 10-5 ~ 10-6 can be achieved when channel bit error rate is 10-2.

                4.Long Transmission Distance ( Line-of-sight Distance)

                    5Km (BER=10-5@9600bps,Standard antenna length 10cm,the height of antenna 1.5m);

                    7Km (BER=10-5@1200bps,Standard antenna length 10cm,the height of antenna 1.5m);

                5.Transparent data transmission

                  Transparent data interface used in transceivers is for meeting many standard or nonstandard user protocols.
                  Any false data generated in air can be filtrated automatically (What has been received is exactly what has been transmitted).

                  Transceiver conversion time:<10ms

                6.Multi-channels,Multi Baud rate

                  Offer 8 channels, if needed, 16 or 32 channels are available to satisfy various configuration of communication under user’s demand at the same time.

                  Baud Rate:1200、2400、4800、9600、19200 etc.

                7.High speed wireless communication and Big data buffer area    

                  When air baud rate is greater than interface baud rate, unlimited data can be continuously transmitted.
                  When baud rate is less than or equal to interface baud rate, can transmit one frame 128 bytes of data.

                8.Intelligent data control and no any extra programs required

                  Even for half duplex communication, no any excessive programs required. All RF system data transmission/reception and
                  other On-the-Fly conversion and control are performed by KYL-300M transceivers automatically.

                9. Lower power consumption & Sleep function

                   With +5V power, the receiving current is less than 30mA, the transmitting current is less than 1.5A, and the sleeping current is less than 20uA.

                10.High reliability, small and light

                   By using monolithic radio-frequency integrated circuit and single-chip MCU, the

                   transceivers have less peripheral circuit s, high reliability, and low failure rate.

                11.Provides square wave transmission function for customers using non-standard coded .


                Application

                 

                AMR Automatic Meter Reading;

                    Building automation, security, wireless monitoring and control of room equipment,Access Control System;

                    Wireless alarm and security systems, Wireless Queuing machine and Wireless medical containers;

                    Wireless POS, PDA wireless smart terminal ;

                    Wireless data transmission, automatic data collection system;

                    Wireless LED display, Responder and intelligent traffic;

                    Converting RS-485 cable to wireless communication, such as PLC。

                 

                 

                Technical specification 
                                                                                   
                                                                            KYL-300M Parameters
                FeaturesRangeRemark
                Power supply D.C.5v3-6v
                Frequency433Mhz450MHz  470Mhz 
                Output power2W --
                Transmitting Current <1.5A  --
                Receiving Current<35mA  --
                Sleeping Current<20uASpecify when place order
                Receiver sensitivity度-123dBm1200bps
                -118Bm9600bps
                Transmission distance3-5KM空旷地,天线高度1.5m
                Dimension80mm*45mm*19mmWithout Antenna connector

                Table: Transmission distance 、Receiver sensitivity and baud rate 
                 
                Baud rate(Bps)Receiver sensitivityTransmission distance(Line-of-sight)
                1200-120dbm1000m
                2400-118dbm800m
                4800-116dbm650m
                9600-113dbm500m
                19200-110dbm300m
                 
                 Pin Definitions

                                                                     300M Interface schematic


                Interface name

                Function description

                Level

                Remark

                1

                GND

                Power Ground



                2

                VCC

                Supply(DC)

                5 V


                3

                RXD/TTL

                Data receiving(TTL level)

                TTL


                4

                TXD/TTL

                Data transmitting(TTL Level)

                TTL

                5

                DGND

                Signal Ground



                6

                A(TXD)

                RS-485 A OR TXD of RS-232



                7

                B(RXD)

                RS-485 B OR RXD of RS-232


                8

                SLEEP

                Sleeping control

                TTL

                Low level active

                9

                TEST

                Internal test



                 

                Table: Channel and RF Frequency

                 

                CH NO.
                FrequencyCH NO.FrequencyCH NO.FrequencyCH NO.Frequency
                1429.0325MHZ2430.0325MHZ3431.0325MHZ4432.0325MHZ
                5433.0325MHZ6434.0325MHZ7435.0325MHZ8436.0325MHZ

                 

                The Function-indicator light

                1、The LED indicator light will glitter red and green for 0.5S once after switched on.
                2、 The LED indicator light will glitter green continually while receiving data from air.
                3、 The LED indicator light will glitter red continuously when transmitting data into air after receiving from COM.

                Timing Diagram

                1、When Module A transmits data and module B receives data

                 That is, the delay time that the terminal A (connected to the module A) sends data to the terminal B
                (connected to the B module) by wireless. Which be fixed to the time for transmitting 15 bytes. This time is related to the air baud rate,
                but not to the interface baud rate. details as follows:



                 aa01.jpg
                Table: Baud rate and delay time

                Baud rate(Bps)

                Delay time(ms)

                19200

                8

                9600

                15

                4800

                30

                2400

                60

                1200

                120

                2、Module transceiver conversion time

                 That is, the time for converting from the receive state to the transmit state, or from the transmit state to the receive state. During this time (100us), the module cannot receive air data.



                aa02.jpg

                How to use KYL series micro power wireless data module

                Power supply:

                     +3.3~5.0V DC,According to the needs of users, it can share the power with other devices, but please select a power supply with a better ripple factor.If conditional, 5V regulators can be used to supply power alone. It is recommended not to use the switching power supply. If you must use the switching power supply, please pay attention to the interference due to switching pulse.In addition, if there are other devices in the system equipment, it must be grounded reliably. Otherwise, it can be self-contained, but it must be completely separated from the city electricity. The maximum output current of the power supply should be more than 1.5 times the maximum operating current of the module.


                Connection diagram for wireless module and computer:

                 

                aa03.jpg
                Packaging accessories

                1、标准配件

                1、Standard accessories

                1、1pc KYL-300M module。

                2、9pin flat cable。 

                3、1pc antenna(about 10cm)

                Pic.:Standard accessories 


                标准配件直头10cm

                2、Selectable accessories

                1、TTL interface programming cable。(for users to set parameters through RS232 interface of the computer)

                    2、Power supply

                    3、Selectable antenna。(Users can choose antenna if need)

                    Pic.:Selectable accessories




                1020L可选配件

                 

                 

                Previous: KYL-300L
                Next: KYL-300U